CU-300 Control Unit
- Operating voltage: 100-240 VAC, 50/60 Hz (auto-switching)
- Current consumption: MAX 0.9A (100VAC) 0.3A (240VAC)
- DC supply to contribution units: ±15V
- Line, Telephone Coupler and Insertion In/Outputs (Unbalanced)
- Input sensitivity: -14dBV/+11dBV
- Input impedance: 33KΩ
- Output level: -14dBV/+11dBV
- Output impedance: 500Ω
- Recorder In/Out (Unbalanced)
- Input sensitivity: -20dBV/+5dBV
- Input impedance: 47KΩ (for L & R channel)
- Adjustment: -20dBV/+5dBV
- Output level: +0/-30dB
- Output impedance: 500Ω
- External Microphone Input (Balanced)
- Input sensitivity: -56dBV
- Adjustment: +6dB/-6dB
- Phantom Power: 12V+/-1V, 2 x 680Ω (+/-2%)
- Output connection: 3.5mm stereo jack
- Headphone Output
- Output level: -8dBV/+2dBV
- Output Impedance: 22Ω
- USB Interface
- USB Connector: USB-C port, USB 2.0 compliant
- DAC Sampling Rates: 32, 44.1, 48 kHz
- ADC Sampling Rates: 8, 11.025, 16, 22.05, 32, 44.1, 48 kHz
- Converter: 16-bit
- USB Interface Power: 5 V, 100 mA maximum via USB connection
|
CH-300 Chairman Unit & DU-300 Delegate Unit
- Gooseneck Microphone:
- Type: Electret Condenser
- Frequency response: 50 to 18,000Hz
- Polar pattern: Cardioid
- Max. SPL for 1% THD: 125dB
- Gooseneck length: 15” / 40 cm
System Limits:
Number of delegate/chairman units connected to a single control unit:
- Maximum total: 50
- Maximum per trunk output: 25
- Maximum cable length per trunk: 328 ft (100m) including the 6.6 ft (2m) cable attached to each unit.
Maximum number of interconnected control units: 3 for a maximum of 150 microphone units.
|